Sinus X-Ray Positioning: Caldwell, Waters and Lateral

Quick answer: A paranasal sinus series is a Caldwell, a Waters and a lateral, taken upright with a horizontal beam so any air–fluid level shows. For the Caldwell, the forehead is raised so the OML is 15° from horizontal and the beam exits at the nasion. For the Waters, the chin goes on the detector with the OML at 37°, and the beam exits at the acanthion. For the lateral, the beam is centered midway between the outer corner of the eye and the ear canal.

Sinus views at a glance

ViewHead positionCentral rayBest for
PA CaldwellForehead on the detector, OML 15° from horizontal (sponge)Horizontal, exits at the nasionFrontal and anterior ethmoid sinuses
Waters (parietoacanthial)Chin on the detector, OML at 37°Horizontal, exits at the acanthionMaxillary sinuses
LateralSide of the face on the detectorHorizontal, midway between outer canthus and EAMAll sinuses from the side, fluid levels

Why upright? Fluid in a sinus settles to the bottom and forms a straight line only if the beam is horizontal. With the patient lying down and a vertical beam, the same fluid just makes the sinus look hazy.

Positioning lines you need

LineFromToUsed for
OML (orbitomeatal line)Outer corner of the eyeEar canal (EAM)PA, Caldwell, Towne, Waters
IOML (infraorbitomeatal line)Lower rim of the orbitEar canalLateral; Towne alternative (37°)
MML (mentomeatal line)ChinEar canalWaters (perpendicular to the detector)
Interpupillary lineOne pupilThe other pupilLateral (perpendicular to the detector)

The OML and the IOML are about 7° apart. That is why the Towne is 30° toward the feet from the OML or 37° from the IOML: the beam ends up in the same place.

Sinuses PA Caldwell

Sinus Caldwell positioning diagram: patient upright, forehead raised on a sponge so the orbitomeatal line is 15 degrees from horizontal, horizontal central ray exiting at the nasion
Sinus Caldwell: OML 15° up, horizontal CR exits at the nasion.

What this view shows: the frontal sinuses and the anterior ethmoids, with the petrous ridges below them in the lower part of the orbits.

  • Upright, facing the detector, nose and forehead near it.
  • Put a 15° sponge between the forehead and the detector, or tilt the head back, so the OML is 15° from horizontal.
  • Keep the beam horizontal: tilting the head instead of the tube is what keeps the fluid levels visible.
  • CR exits at the nasion.

Technical factors

FactorU.S.Metric / Europe
Detector8 × 10 in, portrait18 × 24 cm
SID40 in100 cm
kVp70–8070–80
mAs10–2010–20
GridYesYes

Sinuses Waters (parietoacanthial)

Waters view positioning diagram: chin on the upright detector, head tipped back so the orbitomeatal line forms 37 degrees with the detector, horizontal central ray exiting at the acanthion
Waters: chin up, OML at 37°, horizontal CR exits at the acanthion.

What this view shows: the maxillary sinuses, with the petrous ridges projected just below them, and the frontal sinuses at an angle. It is the most useful single sinus view.

  • Upright, chin resting on the detector.
  • Tip the head back until the OML is at 37° to the detector; the MML is then about perpendicular.
  • CR horizontal, exiting at the acanthion.
  • Open-mouth Waters: same position with the mouth open, to show the sphenoid sinus through the mouth.

Image evaluation: the petrous ridges just below the floor of the maxillary sinuses, and the same distance from the orbits to the skull edge on both sides.

Technical factors

FactorU.S.Metric / Europe
Detector8 × 10 in, portrait18 × 24 cm
SID40 in100 cm
kVp70–8070–80
mAs10–2010–20
GridYesYes

Sinuses lateral

Sinus lateral positioning diagram: upright, side of the face on the detector, horizontal central ray midway between the outer canthus and the external auditory meatus
Sinus lateral: horizontal CR midway between the outer canthus and the EAM.

What this view shows: all four sinus groups from the side, the depth of the frontal sinus and any air–fluid level, including in the sphenoid.

  • Upright, side of the face against the detector.
  • Midsagittal plane parallel, interpupillary line perpendicular.
  • CR horizontal, midway between the outer canthus and the EAM (about 0.5–1 in / 1–2.5 cm behind the outer canthus).

Technical factors

FactorU.S.Metric / Europe
Detector8 × 10 in, landscape18 × 24 cm
SID40 in100 cm
kVp70–8070–80
mAs8–158–15
GridYesYes

Common errors and how to fix them

Error on the imageCauseFix
Petrous ridges over the maxillary sinuses on the WatersChin not raised enoughOML at 37°; raise the chin
Maxillary sinuses foreshortened on the WatersChin raised too muchCheck the 37° angle
No fluid level although the sinus is opaquePatient lying down or beam angledUpright, horizontal beam
Orbits at different distances from the skull edgeRotationMidsagittal plane perpendicular

From my side of the scanner

  • Sinus X-rays are still requested often in my department: Caldwell, Waters and lateral.
  • Standing at the wall Bucky is the normal way. If the patient cannot stay on their feet we do them lying down, knowing that a vertical beam will not show a fluid level.

Sinus X-ray or CT?

For a simple sinus infection, guidelines usually recommend no imaging at all. When imaging is needed, for example before surgery or when symptoms do not go away, CT is the usual test because it shows the drainage paths in detail. Plain X-rays are still used in many places as a quick, low-dose first look.

FAQ

Why do sinus X-rays have to be taken standing?
Standing lets fluid settle into a straight line that shows on the image. Lying down, the fluid spreads out and is much harder to see.

Why did they tip my head back so far?
For the Waters view, raising the chin moves the dense bones at the base of the skull below the maxillary sinuses, so the sinuses are not hidden.

Sources

Part of the X-Ray Positioning Atlas. Previous: skull.

Scroll to Top