Quick answer: A routine shoulder series is an AP (in neutral, external and internal rotation) plus a scapular Y. If the arm is in a sling because of a suspected fracture or dislocation, the arm is not moved: only a neutral AP and a scapular Y. The AP is centered 1 in (2.5 cm) below the coracoid; the Y is centered on the shoulder joint with the beam running along the blade of the scapula. All views: horizontal beam, no tube angle, 40 in (100 cm) SID, grid, breath held.
Shoulder X-ray views at a glance
| View | Body rotation | Centered on | Shows |
|---|---|---|---|
| AP (neutral, external, internal rotation) | 5–10° toward the injured side | 1 in (2.5 cm) below the coracoid | Proximal humerus, glenoid, clavicle, tubercles in profile |
| Scapular Y | Facing the Bucky, 45–60° | Shoulder joint | Dislocation direction, proximal humerus fractures |
| Grashey (true AP glenoid) | 35–45° toward the injured side | Glenohumeral joint | Open joint space, glenoid in profile |
| Inferosuperior axial | Supine, arm abducted | Through the armpit, 15–30° medial | Head on glenoid, Hill-Sachs, Bankart |
Shoulder AP (neutral, external and internal rotation)

What this view shows: the proximal humerus, the glenoid, the acromion, the whole clavicle and the upper scapula. On a normal AP the humeral head slightly overlaps the glenoid. Changing the arm rotation changes which part of the humeral head is in profile.
- Patient standing or seated with the back against the wall Bucky, turned slightly (5–10°) toward the injured side so the scapula is parallel to the detector.
- Center 1 in (2.5 cm) below the coracoid process; CR perpendicular, horizontal beam.
- Collimate to include the whole clavicle up to the sternoclavicular joint, the top of the shoulder and the upper third of the humerus.
- Breath held.
| Rotation | Arm position | In profile |
|---|---|---|
| Neutral | Arm by the side, palm against the thigh | Use this in trauma, when the arm should not be turned |
| External | Palm turned forward, epicondyles parallel to the detector | Greater tubercle, laterally |
| Internal | Back of the hand on the hip, epicondyles perpendicular to the detector | Lesser tubercle, medially; best for a Hill-Sachs defect |
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 10 × 12 in landscape (AP); 8 × 10 in (Grashey) | 24 × 30 cm; 18 × 24 cm |
| SID | 40 in | 100 cm |
| kVp | 60–70 (some protocols 70–80) | 60–70 |
| mAs | 10–18 | 10–18 |
| Grid | Yes (wall Bucky); varies by department | Yes |
Image evaluation: the whole clavicle, the glenoid and the upper scapula on the image, slight overlap of the humeral head and glenoid, and the correct tubercle in profile for the rotation used.
Scapular Y

What this view shows: the scapula end-on, forming a “Y” (the acromion and coracoid are the arms, the body of the scapula the stem). The humeral head should sit over the center of the Y. Under the coracoid means an anterior dislocation; under the acromion, a posterior one. It also shows fractures of the proximal humerus without moving the arm.
- Patient facing the wall Bucky, the injured shoulder against it.
- Turn the body 45–60° away until the scapula is perpendicular to the detector. The exact angle depends on the patient: the beam has to run along the blade of the scapula, through the gap it leaves beside the chest wall.
- Leave the arm as it is (in the sling if the patient has one).
- Center on the shoulder joint; CR perpendicular; breath held.
Image evaluation: the body of the scapula seen as a thin line with no ribs overlapping it, the acromion and coracoid forming a symmetrical Y, and the humeral head over its center.

Grashey (true AP of the glenoid)

What this view shows: the glenohumeral joint space open, with the glenoid in profile. It is used for joint-space narrowing, arthritis and glenoid rim fractures, usually outside emergency trauma.
- Back to the Bucky, turned 35–45° toward the injured side.
- Arm slightly away from the body, in neutral or internal rotation.
- Center on the joint, about 2 in (5 cm) medial and 2 in (5 cm) below the top outer edge of the shoulder; CR perpendicular.
- Stop turning when the middle of the clavicle looks almost end-on.

Inferosuperior axial (axillary)

What this view shows: the humeral head sitting on the glenoid seen from below, the coracoid and the acromion. It confirms dislocation and shows Hill-Sachs and Bankart lesions.
- Patient supine, arm abducted to 90° if they can (at least 20°), palm up.
- Detector on edge against the top of the shoulder, next to the neck.
- Horizontal beam from the side, through the armpit, angled 15–30° medially toward the neck.
- Only if the arm can be moved. Otherwise, the scapular Y or a transthoracic lateral replaces it.
When to angle the tube, and when not to
| Situation | Tube angle |
|---|---|
| AP, scapular Y and Grashey | None. The angle comes from turning the patient, not the tube. |
| Inferosuperior axial | 15–30° medially through the armpit. |
| Arm in a sling (trauma) | None. Neutral AP and scapular Y with the arm left as it is. |
Common errors and how to fix them
| Error on the image | Cause | Fix |
|---|---|---|
| Patient turned too far (the most common error) | Over-rotating the body on the AP or the Y | AP: only 5–10°. Y: turn until the beam runs along the scapula, not more |
| Clavicle cut off | Field too small or centered too far out | Include the whole clavicle up to the sternoclavicular joint |
| Ribs over the scapula on the Y | Wrong amount of rotation | Adjust until the scapular body is a thin line clear of the ribs |
| Joint space closed on the Grashey | Not turned enough | Turn further, 35–45° |
| Wrong tubercle in profile | Arm rotation not as requested | Check the epicondyles: parallel for external, perpendicular for internal |
From my side of the scanner
- Our routine is AP in the rotations plus a Y. If the arm comes in a sling, we do not touch it: AP and Y only.
- The two errors I see most: turning the patient too far, and cutting off the clavicle.
- On the Y, look at the scapula, not at the number. What really matters is that the beam goes in through the gap the scapula leaves; the 45–60° is only a starting point, and the right angle changes from one patient to another.
Radiation dose
A shoulder series is a low-dose exam, roughly 0.01 mSv (about 1 mrem) per study, around a day of natural background radiation. The thyroid is near the field, so tight collimation matters.
FAQ
Why do I have to turn for the shoulder X-ray?
The shoulder blade sits at an angle on the back of the chest. Turning lines it up with the X-ray beam so the joint and the scapula can be seen properly.
Will they take my arm out of the sling?
Not if a fracture or dislocation is suspected. The views are chosen so the arm can stay in the sling.
Why are there several pictures of the same shoulder?
Each view shows a different part: the AP in different rotations shows the tubercles of the humerus, and the Y shows whether the shoulder is dislocated and in which direction.
Sources
- Radiopaedia: Shoulder series
- Radiopaedia: Shoulder (AP view)
- Radiopaedia: Shoulder (AP glenoid / Grashey view)
- University of Missouri, Radiographic Procedures (Carla M. Allen): Shoulder
- AuntMinnie: Getting the most from shoulder positioning
- Wikimedia Commons: normal shoulder radiographs by Mikael Häggström, M.D. (CC0)
- RadiologyInfo.org: Radiation dose in X-ray and CT exams
Part of the X-Ray Positioning Atlas. Previous: humerus. Next: clavicle and AC joint.