Pelvis X-Ray Positioning: AP, Inlet, Outlet and Judet Views

Quick answer: The basic pelvis view is an AP: supine, feet rotated 15° inward, CR to the midline about 5 cm (2 in) above the symphysis, 14 × 17 in (35 × 43 cm) landscape, grid, 40 in (100 cm) SID. In trauma, inlet (40° toward the feet) and outlet (20–45° toward the head) views show the pelvic ring in other planes. No internal rotation if a hip fracture is suspected. For acetabular fractures, the two Judet obliques (iliac and obturator, 45° each) show the iliac wing, the ischium and the obturator foramen.

Pelvis views at a glance

ViewCentral rayCentered onUsed for
APPerpendicularMidline, 5 cm above the symphysisEvery pelvis and most hips
Inlet40° toward the feetMidline at ASIS levelPelvic ring disruption, front-back displacement
Outlet20–35° (men), 30–45° (women) toward the headMidline, 3–5 cm below the symphysisSacrum, pubic rami, up-down displacement
Iliac oblique (Judet)Perpendicular, injured side turned 45° down2 in (5 cm) below and 2 in medial to the ASISIliac wing, posterior column, ischium
Obturator oblique (Judet)Perpendicular, injured side turned 45° up2 in (5 cm) below the ASISObturator foramen, anterior column, pubic and ischial rami

Pelvis AP

Pelvis AP positioning diagram: supine, both feet rotated 15 degrees inward, central ray to the midline about 5 cm above the symphysis
Pelvis AP: feet turned in 15°, CR midline 5 cm above the symphysis.

What this view shows: the whole pelvic ring, both hips, the sacrum and the sacroiliac joints, and the proximal femurs.

  • Supine, pelvis level: both ASIS the same distance from the table.
  • Feet rotated 15° inward so the femoral necks are shown in full length (not with a suspected fracture).
  • CR perpendicular to the midline, midway between the level of the ASIS and the symphysis (about 5 cm above it).
  • Include the iliac crests and the lesser trochanters.

Technical factors

FactorU.S.Metric / Europe
Detector14 × 17 in, landscape35 × 43 cm
SID40 in100 cm
kVp75–8575–85
mAs15–2515–25
GridYesYes

Image evaluation: the obturator foramina and the iliac wings symmetrical (no rotation), the sacrum centered over the symphysis, the lesser trochanters barely visible.

Pelvis inlet

Pelvis inlet positioning diagram: supine, central ray angled 40 degrees toward the feet at the level of the ASIS
Pelvis inlet: CR 40° toward the feet, midline at the ASIS.

What this view shows: the pelvic ring from above, as if looking down into the pelvis. It shows whether one side has been pushed forward or backward.

  • Supine, legs straight, no rotation.
  • CR 40° toward the feet, to the midline at the level of the ASIS.

Pelvis outlet

Pelvis outlet positioning diagram: supine, central ray angled 40 degrees toward the head, centered below the symphysis
Pelvis outlet: CR toward the head, 20–35° for men, 30–45° for women.

What this view shows: the sacrum and its foramina and the pubic and ischial rami without overlap; it shows whether one side of the pelvis has moved up or down.

  • Supine, legs straight.
  • CR toward the head: 20–35° for men, 30–45° for women, centered 3–5 cm below the symphysis.

Inlet and outlet in practice: in many trauma centers these have been replaced by CT, which shows the pelvis in every plane. They are still taken where CT is not immediately available and for follow-up of pelvic fractures.

Judet views: iliac and obturator obliques

What these views show: the acetabulum and its two columns in two planes at right angles. They are the classic views for acetabular fractures and are taken as a pair. Each one is named after what it shows best on the injured side.

Iliac oblique (iliac wing view)

Pelvis iliac oblique (Judet) positioning diagram: patient turned 45 degrees with the injured side down, central ray 2 inches below and 2 inches medial to the ASIS
Iliac oblique: injured side down 45°, CR 2 in below and 2 in medial to the ASIS.
  • Supine, then turn the patient 45° toward the injured side (injured side down), with a sponge under the raised side.
  • The iliac wing of the injured side lies parallel to the detector and is seen flat (en face).
  • CR perpendicular, 2 in (5 cm) below and 2 in (5 cm) medial to the ASIS of the injured side.
  • Shows: the whole iliac wing, the posterior column (ilioischial line) down to the ischium and ischial tuberosity, and the anterior rim of the acetabulum.

Obturator oblique (obturator foramen view)

Pelvis obturator oblique (Judet) positioning diagram: patient turned 45 degrees with the injured side up, central ray 2 inches below the ASIS
Obturator oblique: injured side up 45°, CR 2 in below the ASIS.
  • Supine, then raise the injured side 45° on a sponge (injured side up).
  • The obturator foramen of the injured side opens up and is seen as a full ring.
  • CR perpendicular, 2 in (5 cm) below the ASIS of the raised side.
  • Shows: the obturator foramen, the superior pubic and ischiopubic rami around it, the anterior column (iliopectineal line) and the posterior rim of the acetabulum.

In practice: in trauma centers CT with 3D reconstructions has replaced the Judet views for planning surgery, but they are still used for follow-up and where CT is not immediately available. Detector 10 × 12 in (24 × 30 cm) portrait, grid, 40 in (100 cm) SID; if a pelvic fracture is unstable, move the patient only as the doctor allows.

Common errors and how to fix them

Error on the imageCauseFix
Obturator foramina unequalPelvis rotatedLevel the ASIS; small sponge under the low side
Lesser trochanters prominentFeet turned out15° inward (unless fracture)
Iliac crests or trochanters cut offDetector centered too high or lowCenter between ASIS level and symphysis; landscape
Iliac wing or obturator foramen not open on the Judet viewsRotation not 45°, or turned the wrong wayIliac: injured side down; obturator: injured side up; check with an angle sponge

Radiation dose

An AP pelvis is about 0.6 mSv, roughly two months of natural background radiation. Routine gonadal shielding is no longer recommended by most professional bodies; see why many hospitals stopped using lead shields.

FAQ

Why don’t they put a lead shield on me for a pelvis X-ray?
Because on a pelvis image the shield can hide the exact area being examined and force a repeat, and modern doses are low. Most guidelines have dropped routine shielding.

Is a pelvis X-ray safe in pregnancy?
If there is any chance you are pregnant, tell the technologist before the X-ray. The doctor will weigh the need; other tests may be used. See imaging during pregnancy.

Sources

Part of the X-Ray Positioning Atlas. Previous: hip. Next section: cervical spine.