Quick answer: A rib series is an AP plus a 45° oblique of the injured side. Ribs above the diaphragm are taken on a deep breath in, centered on T7, upright if possible. Ribs below the diaphragm are taken on breathing out, supine, with the bottom of the detector at the iliac crests. For the oblique, the injured side goes toward the detector. The sternum is taken as a 15–20° RAO, so it projects over the heart, plus a lateral when needed.
Rib and sternum views at a glance
| View | Patient | Central ray | Breathing |
|---|---|---|---|
| Ribs AP, above the diaphragm | Upright, back to the detector | T7, halfway between the spine and the side wall | Deep breath in and hold |
| Ribs AP, below the diaphragm | Supine | Midway between the xiphoid and the lower rib margin | Breathe out and hold |
| Ribs 45° oblique | Injured side toward the detector, other side turned away | Midway between the spine and the side wall | Same as the AP |
| Sternum RAO | Facing the detector, right front turned 15–20° toward it | Mid-sternum, about 1 in (2.5 cm) left of the spine | Slow, shallow breathing |
| Sternum lateral | Upright, side to the detector, shoulders back | Mid-sternum | Deep breath in and hold |
Ribs AP above the diaphragm

What this view shows: ribs 1 to 10 above the diaphragm, the area where most rib fractures happen.
- Upright if the patient can: the diaphragm drops lower and it is less painful than lying down.
- Back against the detector, injured side centered: CR halfway between the spine and the side wall of the chest.
- Top of the detector about 1.5 in (4 cm) above the shoulders; CR at the level of T7.
- Expose on a deep breath in, held.
- For both sides, use a landscape detector centered on the midline.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 14 × 17 in, portrait (one side) | 35 × 43 cm |
| SID | 40 in | 100 cm |
| kVp | 65–75 | 65–75 |
| mAs | 10–20 | 10–20 |
| Grid | Yes | Yes |
Ribs AP below the diaphragm

What this view shows: ribs 9 to 12, which sit over the upper abdomen. They need more exposure than the upper ribs because the abdomen is denser than the air-filled lungs.
- Supine, injured side centered.
- Bottom of the detector at the iliac crests.
- CR midway between the xiphoid and the lower rib margin, on the injured side.
- Expose on breathing out: the diaphragm rises and the lower ribs are seen against the abdomen.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 14 × 17 in, portrait | 35 × 43 cm |
| SID | 40 in | 100 cm |
| kVp | 70–80 | 70–80 |
| mAs | 20–30 | 20–30 |
| Grid | Yes | Yes |
Ribs 45° oblique

What this view shows: the side (axillary) part of the ribs straightened out. On the AP that part is curved and foreshortened, and fractures there are easy to miss.
- Injured side toward the detector, turning the other side 45° away. For pain at the back, that is a posterior oblique (RPO for the right side); for pain at the front, the patient can face the detector and turn the injured side away (anterior oblique).
- CR midway between the spine and the side wall of the injured side.
- Same breathing as the AP: in for the upper ribs, out for the lower ribs.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 14 × 17 in, portrait | 35 × 43 cm |
| SID | 40 in | 100 cm |
| kVp | 65–80 | 65–80 |
| mAs | 10–25 | 10–25 |
| Grid | Yes | Yes |
Sternum RAO (15–20°)

What this view shows: the whole sternum, from the jugular notch to the xiphoid. Turning the patient moves the sternum off the spine and over the heart, which gives it an even background.
- Facing the detector, right front turned 15–20° toward it (RAO). Broad chests need less turn, thin chests more.
- CR to the middle of the sternum, about 1 in (2.5 cm) left of the spine and halfway between the jugular notch and the xiphoid.
- Breathing technique: a long exposure (2–3 s) with slow, shallow breathing blurs the ribs and lung markings over the sternum. If the patient cannot do it, expose on breathing out.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 10 × 12 in, portrait | 24 × 30 cm |
| SID | 40 in | 100 cm |
| kVp | 70–80 | 70–80 |
| mAs | 15–30 (long time) | 15–30 (long time) |
| Grid | Yes | Yes |
Sternum lateral
- Upright, side against the detector, shoulders and arms drawn well back so they do not cover the sternum.
- CR to mid-sternum, at a long SID (72 in / 180 cm) to reduce magnification.
- Deep breath in and hold.
Common errors and how to fix them
| Error on the image | Cause | Fix |
|---|---|---|
| Too few ribs above the diaphragm | Poor inspiration or lying down | Upright, deep breath in |
| Lower ribs too light or too dark | Wrong breathing or exposure | Breathe out; more exposure than for the upper ribs |
| Fracture at the side missed | No oblique | Add the 45° oblique of the injured side |
| Sternum over the spine | Not enough rotation | 15–20° RAO |
| Ribs sharp over the sternum | Breath held instead of breathing technique | Long exposure with slow, shallow breathing |
From my side of the scanner
- AP plus an oblique, always. That is the standard rib series in my department.
- Ribs above the diaphragm on inspiration, ribs below on expiration.
- We do not place a skin marker on the painful spot.
- A chest X-ray is not usually added to the rib series where I work.
- The sternum is requested now and then, after an impact or from an outpatient clinic.
Radiation dose
A rib series is a low dose, a few tenths of a mSv at most, a small fraction of a chest CT (about 6–7 mSv). See how CT doses compare.
FAQ
Why did they X-ray my ribs twice?
The straight-on view and the angled view see different parts of the curve of each rib. A crack at the side can be invisible on one and clear on the other.
Can a rib fracture be missed on an X-ray?
Yes. Small or non-displaced fractures, and breaks in the cartilage at the front, may not show at first. Treatment is usually the same, so the doctor often goes by the exam and the pain.
Why was I asked to breathe during the sternum X-ray?
Slow breathing during a long exposure blurs the ribs and lungs in front of and behind the sternum, so the sternum itself stands out.
Sources
- University of Missouri, Radiographic Procedures (Carla M. Allen)
- RadiologyInfo.org: Radiation dose in X-ray and CT exams
Part of the X-Ray Positioning Atlas. Previous: chest. Next: abdomen.