Quick answer: The sacrum AP uses a 15° angle toward the head and the coccyx AP a 10° angle toward the feet, both centered on the midline about 2 in (5 cm) above the symphysis. The lateral is taken on the side, centered 3–4 in (8–10 cm) behind the ASIS. Ask the patient to empty the bladder first. Grid, 40 in (100 cm) SID, tight collimation.
Sacrum and coccyx views at a glance
| View | Central ray | Centered on | Detector |
|---|---|---|---|
| Sacrum AP | 15° toward the head | Midline, 2 in above the symphysis | 10 × 12 in (24 × 30 cm) |
| Coccyx AP | 10° toward the feet | Midline, 2 in above the symphysis | 8 × 10 in (18 × 24 cm) |
| Lateral | Perpendicular | 3–4 in behind the ASIS | 10 × 12 in (24 × 30 cm) |
Sacrum AP

What this view shows: the sacrum and the sacroiliac joints without foreshortening. The sacrum tilts backward, so the beam is angled toward the head to meet it at right angles.
- Empty bladder first; gas and stool in the bowel can cover the sacrum.
- Supine, legs straight, no rotation.
- CR 15° toward the head, midline about 2 in (5 cm) above the symphysis.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 10 × 12 in, portrait | 24 × 30 cm |
| SID | 40 in | 100 cm |
| kVp | 75–85 | 75–85 |
| mAs | 20–30 | 20–30 |
| Grid | Yes | Yes |
Coccyx AP

What this view shows: the coccyx projected above the symphysis instead of behind it. The coccyx curves forward, so the beam is angled toward the feet.
- Empty bladder first.
- Supine, legs straight.
- CR 10° toward the feet, midline about 2 in (5 cm) above the symphysis.
- Collimate tightly to the coccyx.
Sacrum and coccyx lateral

What this view shows: the sacrum and coccyx in profile, the best view for a fracture or a displaced coccyx.
- Lying on the side, hips and knees bent.
- Support under the waist so the spine is level.
- Sacrum: CR 3–4 in (8–10 cm) behind the ASIS. Coccyx alone: CR lower, over the coccyx, with tighter collimation.
- A lead blocker behind the patient cuts scatter.
Technical factors
| Factor | U.S. | Metric / Europe |
|---|---|---|
| Detector | 10 × 12 in, portrait | 24 × 30 cm |
| SID | 40 in | 100 cm |
| kVp | 85–95 | 85–95 |
| mAs | 30–50 | 30–50 |
| Grid | Yes | Yes |
Common errors and how to fix them
| Error on the image | Cause | Fix |
|---|---|---|
| Coccyx hidden behind the symphysis | No angle or wrong direction | 10° toward the feet |
| Sacrum foreshortened | No angle | 15° toward the head; more for a large lordosis |
| Bowel gas over the sacrum | Preparation | Empty bladder; note it if it cannot be avoided |
| Sacrum too dark or too light on the lateral | High scatter, thick area | Tight collimation, lead blocker, correct kVp |
Radiation dose
A sacrum or coccyx series is a moderate dose, lower than a lumbar series because the field is smaller. The coccyx views are often skipped when the result will not change the treatment, since most coccyx injuries are treated the same way.
FAQ
Why do I need to empty my bladder?
A full bladder sits in front of the sacrum and coccyx and makes them harder to see.
Will an X-ray show a bruised tailbone?
It shows fractures and displacement of the coccyx. A bruise or a sprain without a fracture does not show on an X-ray.
Sources
- Radiopaedia: Sacrum and coccyx (lateral view)
- University of Missouri, Radiographic Procedures (Carla M. Allen)
- RadiologyInfo.org: Radiation dose in X-ray and CT exams
Part of the X-Ray Positioning Atlas. Previous: lumbar spine.